Special Test

Painful Arc Test

The client lifts the arm out to the side and back down; pain in the middle part of the movement suggests subacromial or rotator cuff pain.

Suits
Clinical and rehab
Result
Result (negative / positive)

See it done

A demonstration by Physiotutors on YouTube (2:00). GymEd didn't make it, so where it differs from the steps below, follow the steps.

How to run it

  1. Client stands (or sits) with arms by the sides. Stand where you can see the shoulder and the client's face.
  2. Ask the client to slowly lift the straight arm out to the side (active abduction), thumb pointing up, as high as they can, then slowly lower it.
  3. Ask them to tell you where in the movement pain starts and where it stops, on the way up and on the way down. Test the other side to compare.
  4. Positive: pain in the middle part of the lift, usually between about 60 and 120 degrees, with less or no pain below and above that range. It suggests subacromial or rotator cuff related shoulder pain.

Equipment

None

Safety

Let the client move at their own pace and stop if pain is severe. Skip it with a suspected fracture or soon after a dislocation. A positive is one finding, not a diagnosis: read it with the history and other tests.

How accurate is it

Subacromial pain (impingement syndrome)
Sensitivity 0.59, specificity 0.61, LR+ 1.57, LR- 0.63 (Zhao 2024, PMID 39702033; Adults with shoulder symptoms seen in shoulder clinics)
Rotator cuff disease
LR+ 3.7, LR- 0.36 (Hermans 2013, PMID 23982370; Referred patients examined by specialists; prevalence 33% to 81% in level 1-2 studies)

Sensitivity is how often the test is positive when the problem is there. Specificity is how often it is negative when it is not. Each figure comes from the study named, in its group of people and against its reference standard. A positive is one finding, not a diagnosis.

Reliability

ICC
Inter-rater kappa 0.56 (42 adults with acute shoulder injury, emergency physicians; Schmidt 2021, PMID 34503466); 0.45 to 0.67 grouped with empty can and external rotation resistance (55 clinic patients; Michener 2009, PMID 19887215)

Each figure comes from the study named beside it, in that study's population and protocol. Check they match your clients before you read a change as real.

Sources

  • Protocol Kessel L, Watson M. The painful arc syndrome. Clinical classification as a guide to management. J Bone Joint Surg Br 1977;59(2):166-72. PMID 873977 Michener LA, Walsworth MK, Doukas WC, Murphy KP. Reliability and diagnostic accuracy of 5 physical examination tests and combination of tests for subacromial impingement. Arch Phys Med Rehabil 2009;90(11):1898-903. PMID 19887215
  • Reference Physiopedia
14 days free

Test it, log it, see the change.

Build the program, log the session and the test in the same record, and re-test in a few weeks.

  • No credit card
  • Set up with you, one to one
  • Australian owned