See it done
A demonstration by IDDSI on YouTube (1:25). GymEd didn't make it, so where it differs from the steps below, follow the steps.
How to run it
- Get the current IDDSI Framework detailed definitions and testing methods, free from iddsi.org. Use the level numbers and names exactly as IDDSI gives them.
- From the client's swallowing plan, record the thinnest drink allowed (0 Thin, 1 Slightly Thick, 2 Mildly Thick, 3 Moderately Thick or 4 Extremely Thick) and the most advanced food allowed (3 Liquidised, 4 Pureed, 5 Minced & Moist, 6 Soft & Bite-Sized, 7 Easy to Chew or 7 Regular), or that nothing is allowed by mouth.
- To check a drink at levels 0 to 3, do the IDDSI Flow Test: remove the plunger from a 10 mL slip tip syringe, seal the nozzle with a finger, fill to the 10 mL line, then let it flow while timing 10 seconds and seal it again. Less than 1 mL left is level 0, 1 to 4 mL level 1, 4 to 8 mL level 2, more than 8 mL level 3.
- For level 4 drinks and for foods, use the fork drip, spoon tilt and fork pressure tests in the IDDSI testing methods; level 6 pieces are no larger than 1.5 cm for adults and 8 mm for children.
- Score the IDDSI Functional Diet Scale: count the levels from the drink level up to the food level, inclusive (food level minus drink level plus 1). Nothing by mouth scores 0, one level only scores 1. Add a + when a more advanced item is being trialled in therapy.
Equipment
Current IDDSI Framework detailed definitions and testing methods (free at iddsi.org); to check a drink or food: a 10 mL slip tip syringe measuring 61.5 mm from the zero line to the 10 mL line, a stopwatch, a fork and a spoon. Optional: Chopsticks (where a fork is not available)
Safety
The IDDSI tests check a food or drink, not the client: they confirm a product matches its level at the time of testing. Only a clinician's full swallowing assessment sets a client's levels, so refer to a speech pathologist before any change, and promptly for coughing or choking with food or drink, chest infections or weight loss. Test drinks at serving temperature, twice or more, and use only a syringe that measures 61.5 mm from the zero line to the 10 mL line.
Reliability
- ICC
- IDDSI-FDS: average ICCs 0.965, 0.966, 0.971 and 0.939 across four batches of 43 survey responses, 170 clinicians from 29 countries scoring 16 written cases, model not stated (Steele 2018, PMID 29428348, accepted manuscript); weighted kappa 1.00 between three raters scoring 67 FEES reports (Silva-Carvalho 2026, PMID 42543420)
Each figure comes from the study named beside it, in that study's population and protocol. Check they match your clients before you read a change as real.
Sources
- Protocol Cichero JA, Lam P, Steele CM, Hanson B, Chen J, Dantas RO, Duivestein J, Kayashita J, Lecko C, Murray J, Pillay M, Riquelme L, Stanschus S. Development of International Terminology and Definitions for Texture-Modified Foods and Thickened Fluids Used in Dysphagia Management: The IDDSI Framework. Dysphagia 2017;32(2):293-314. PMID 27913916 International Dysphagia Diet Standardisation Initiative. Complete IDDSI Framework Detailed Definitions 2.2 (April 2026) and IDDSI Testing Methods 2.0 (July 2019). CC BY-SA 4.0. https://iddsi.org (GymEd is not the official IDDSI website) Steele CM, Namasivayam-MacDonald AM, Guida BT, Cichero JA, Duivestein J, Hanson B, Lam P, Riquelme LF. Creation and Initial Validation of the International Dysphagia Diet Standardisation Initiative Functional Diet Scale. Arch Phys Med Rehabil 2018;99(5):934-944. PMID 29428348
- Reference iddsi.org