Free 14-day trial, no card Prices double on 1 Feb 2027: subscribe before then and keep today's price while you stay. Start free
How it works AI

Who it's for

Exercise physiologists Physiotherapists Personal trainers and S&C NDIS providers Schools and HPE
Pricing Free tools Log in Start free for 14 days
Balance Sub-maximal

Timed 360 Degree Turn Test (360TT)

The client turns one full circle on the spot at a comfortable speed; the time (and if wanted the number of steps) is recorded for each direction. A quick check of turning in Parkinson's and older adults.

Effort
Sub-maximal
Suits
Older adults, clinical and rehab and neurological clients
Result
Seconds (s); lower is better
Practice trial
Recommended

How to run it

  1. Put a strip of tape or a marker on the floor. The client stands at the marker, facing forward, feet comfortably apart and pointing at the tape, arms by their sides, in usual shoes.
  2. Explain the task: on 'Go', turn one full circle on the spot at a comfortable speed of their own choosing and stop facing forward again. Allow one practice turn.
  3. Start the stopwatch on 'Go' and stop it when the client's shoulders are back facing the starting direction.
  4. Time three turns to the left (anticlockwise) and three to the right (clockwise). Record the mean time for each direction.
  5. If counting steps, count the steps taken to complete each turn and record the mean for each direction.
  6. Turn without a walking aid where it is safe, as in the published studies. If an aid is needed, record it and compare only with tests done the same way.
  7. Keep the footwear, the order of directions and the time since the last medication dose the same at each visit.

Equipment

Stopwatch; a tape line or marker on the floor

Safety

Stand close to the client, ready to steady them: turning on the spot can bring on freezing and unsteadiness, especially in Parkinson's. Stop the trial if they freeze for more than a moment, stagger or reach for support, and record what happened. Allow a short rest between turns if they feel dizzy.

Reliability

Reliability
Excellent intrarater, interrater and test-retest in 38 people with Parkinson's (Soke 2020, PMID 32297254; test-retest ICC 0.860 to 0.932 as cited by Soke 2026, PMID 41528676); 0.957 (dominant side) and 0.916 (non-dominant side), ICC(2,1), 33 people with mild to moderate Alzheimer's disease, 7 to 10 days apart (Soke 2026, PMID 41528676); 0.77 for time and 0.80 for steps in 15 people with Parkinson's, retested on the next day and a week later (Schenkman 1997, PMID 8996460; figures read on the Shirley Ryan AbilityLab page)
SEM
not established in Parkinson's (Soke 2020 full text not read); 0.33 s turning to the dominant side and 0.31 s to the non-dominant side in 33 people with Alzheimer's disease (Soke 2026, PMID 41528676; labelled 'SEM95' in the paper but the value is the ordinary SEM)

Each figure comes from the study named beside it, in that study's population and protocol. Check they match your clients before you read a change as real.

Sources

  • Protocol Soke F, Guclu-Gunduz A, Ozkan T, Ozkul C, Gulsen C, Kocer B. Reliability and validity of the timed 360° turn test in people with Parkinson's disease. Eur Geriatr Med 2020;11(3):417-426. PMID 32297254 Soke F, Ataoglu NEE, Gulsen C, Yorulmaz DK, Gulfirat FN, Bora HAT. Timed 360° turn test in people with Alzheimer's disease: a reliability and validity study. Ir J Med Sci 2026;195(2):1021-1028. PMID 41528676 (protocol description, citing Shiu 2016) Shiu CH, Ng SS, Kwong PW, Liu TW, Tam EW, Fong SS. Timed 360° turn test for assessing people with chronic stroke. Arch Phys Med Rehabil 2016;97(4):536-544. PMID 26694578
  • Reference Shirley Ryan AbilityLab
14 days free

Test it, log it, see the change.

Build the program, log the session and the test in the same record, and re-test in a few weeks.

  • No credit card
  • Set up with you, one to one
  • Australian owned